Verify that installed doors meet fire, security, and accessibility standards by checking clearances, hardware, frame alignment, and documentation. This checklist helps engineers and buyers catch compliance failures before final acceptance.
- Check frame squareness, clearances, and swing direction before final acceptance.
- Verify fire door hardware, self-closing devices, and gasket continuity.
- Confirm accessibility clearances and force requirements for accessible routes.
- Record all findings with photos and reference the approved installation drawings.
- Do not accept the job until red flags are documented and corrected in writing.
A door is more than an opening in a wall. It is a controlled access point that must perform under fire, security, and accessibility conditions. When the last hinge is set and the frame is fixed, the installation is not finished. The compliance check is where the work is either accepted or sent back for correction.
This checklist is written for site inspectors, project engineers, and buyers who need to verify that a finished door meets the specified requirements. It groups checks by theme so the inspection can move through the door in a logical order. Use it during a final site walk, or as a pre-handover audit.
What to verify before you start
Before walking the site, gather the approved drawings, the product data sheets, and the installation method statement. The approved drawings show the door set type, frame depth, swing direction, and hardware schedule. The product data sheets state the fire rating, security level, and accessibility force values. The installation method statement explains how the frame was fixed and how the door leaf was hung.
Without these documents, the inspection is a guess. You can measure a gap, but you cannot say whether the gap is correct until you know what was specified. Keep a notebook or a tablet ready for photos. A photo of a crooked frame or a missing gasket is worth more than a verbal note.
Walk the site with a tape measure, a level, a door swing gauge, and a flashlight. A flashlight helps you see the gasket and the weather stripping. A level checks the frame plumb. A tape measure checks the clearances.
Frame alignment and structural fixings
The frame must be plumb, level, and square. A frame that is out of square will force the door leaf to bind, even if the leaf itself is straight. Check each corner of the frame. Place the level on the jamb and note any deviation from vertical. Check the head and sill for horizontal alignment.
Look at the fixings. The frame should be fixed to the structure in a way that does not compromise the fire rating. If the frame is fixed through a fire-rated partition, the fixings must be in the correct positions and the fire seal must be intact. If the fixings are too close to the edge, the frame may crack under thermal movement.
Check the frame depth. The frame depth must match the product data sheet. A shallow frame in a deep opening can leave a gap that allows heat and smoke to pass during a fire. A deep frame in a shallow opening can prevent the frame from being fixed properly.
Red flags to watch for:
- Frame out of plumb or level.
- Fixings missing or in the wrong positions.
- Gap between frame and structure that is not sealed.
- Frame depth that does not match the approved drawing.
Door leaf fit and clearances
The door leaf must swing freely without binding on the frame or the floor. Check the clearances. A standard door set usually requires a specific gap around the leaf. The top gap, the side gaps, and the bottom gap all affect the door operation.
Check the bottom gap. If the door is close to the floor, it may drag when the door is slightly out of level. If the gap is too large, the door may not close properly, which can compromise fire and security performance.
Check the side and top gaps. These gaps must be even. If one side is tighter than the other, the door will rub when it swings. This creates friction, which can cause the self-closing device to fail over time.
Check the door leaf for warping. A leaf that is twisted will not close properly. Look at the corners. A twisted leaf will show a gap at one corner and contact at the opposite corner. This is a sign of poor storage, poor transport, or poor installation.
Red flags to watch for:
- Door leaf binds when swung through its full arc.
- Uneven top or side gaps.
- Bottom gap too small or too large.
- Door leaf twisted or warped.
Fire door hardware and self-closing devices
Fire doors require specific hardware. The handle, the latch, and the self-closing device must be the approved type. Check the self-closing device. It must be mounted correctly and must close the door with the required force.
Test the self-closing device. Open the door fully and let go. The door should close in a controlled way. If the door slams, the device is adjusted too fast. If the door sticks open, the device is adjusted too slow. If the door does not close at all, the device may be faulty or misaligned.
Check the fire latch. A fire door must stay closed under fire conditions. The latch must engage the strike plate. If the latch is set too far back, the door may not latch properly. If the latch is set too far forward, the door may not close fully.
Check the gasket. The gasket must be continuous around the perimeter of the door leaf. If the gasket is cut, crushed, or missing, the fire rating is compromised. A small cut in the gasket can allow smoke to pass.
Red flags to watch for:
- Self-closing device adjusted incorrectly.
- Fire latch not engaging the strike plate.
- Gasket cut, crushed, or missing.
- Hardware not the approved type.
Security features and locking hardware
Security doors require specific locking hardware. Check the lock cylinder, the deadbolt, and the door closer. The lock must be the approved type and must be installed correctly.
Check the lock cylinder. It must be the correct grade and must be installed in the door leaf without damage. If the cylinder is scratched or misaligned, the lock may not operate smoothly.
Check the deadbolt. The deadbolt must extend the full required length. If the deadbolt is too short, it may not engage the strike plate. If the deadbolt is too long, it may bind.
Check the door closer. The closer must hold the door in the closed position. If the closer is too weak, the door may be forced open. If the closer is too strong, it may damage the door leaf.
Red flags to watch for:
- Lock cylinder scratched or misaligned.
- Deadbolt not extending the full length.
- Door closer holding the door incorrectly.
- Hardware not the approved type.
Accessibility requirements and clearances
Accessible doors must meet specific requirements. The door leaf width must be sufficient for a wheelchair to pass. The opening width must be clear of any obstructions. The handle must be at the correct height.
Check the door leaf width. The clear opening must be wide enough for the required access. Measure the clear opening from the frame to the frame, not from the leaf to the leaf. The leaf itself must not interfere with the passage.
Check the opening width. The opening must be clear of any obstructions. If there is a step, a ramp, or a threshold, it must be within the allowed height. A step that is too high can block wheelchair access.
Check the handle height. The handle must be at the correct height for a seated user. If the handle is too high, a seated user cannot operate it. If the handle is too low, a standing user may not be able to operate it comfortably.
Check the force. The door must open with the required force. If the door is too heavy, a user with limited strength may not be able to open it. If the door is too light, it may swing open unexpectedly.
Red flags to watch for:
- Clear opening too narrow for wheelchair access.
- Threshold height above the allowed limit.
- Handle height not within the accessible range.
- Door force too high for a user with limited strength.
Documentation and final acceptance
The final step is to document the findings. Write down every check, the result, and any deviation from the specification. Take photos of any issues. A photo of a missing gasket is useful evidence. A photo of a crooked frame is useful evidence.
If there are any deviations, they must be corrected before final acceptance. The contractor must correct the issues and provide a re-inspection. Do not accept the job with open issues. An open issue can become a safety risk or a compliance failure later.
Keep the completed checklist with the project records. It is part of the as-built documentation. It shows that the door was inspected and that the compliance checks were performed.
Red flags to watch for:
- No documentation of the inspection.
- Deviations not corrected before acceptance.
- Checklist not kept with the project records.
- Verbal promises instead of written corrections.
Quick reference table
| Check | What to verify | Pass condition |
|---|---|---|
| Frame plumb | Level on each jamb | Within specified tolerance |
| Frame level | Level on head and sill | Within specified tolerance |
| Frame square | Diagonal measurements equal | Diagonals within tolerance |
| Door clearances | Top, side, and bottom gaps | Match approved drawing |
| Self-closer | Door closes smoothly | Closes in controlled time |
| Fire latch | Latch engages strike plate | Latch fully engaged |
| Gasket | Continuity around leaf | No cuts or gaps |
| Accessible width | Clear opening width | Meets accessibility standard |
| Handle height | Height from floor | Within accessible range |
| Door force | Opening force | Within specified limit |
Final inspection tips
Keep the inspection short and focused. Do not try to check every detail in one pass. Group the checks by theme and move through them in order. This reduces the chance of missing an issue.
Use the approved drawings as your reference. If the drawing says the top gap is 10 mm, check for 10 mm. If the drawing says the frame must be fixed with specific screws, check for those screws.
Do not rely on visual inspection alone. Measure. Measure the gaps. Measure the frame. Measure the clearances. A door that looks straight may be out of square. A door that looks aligned may have a binding point.
If you find a red flag, stop. Do not accept the door until the issue is corrected. A red flag is a sign that the installation does not meet the specification. It is not a minor issue. It is a compliance failure.
Frequently asked questions
How many clearances should I check on a door leaf?
Check the top, both sides, and the bottom. Each gap must match the approved drawing. An uneven gap can cause binding and compromise performance.
What is the main purpose of the fire door gasket?
The gasket seals the perimeter of the door leaf to prevent smoke and heat from passing. If the gasket is cut or missing, the fire rating is compromised.
How do I test the self-closing device?
Open the door fully and release it. The door should close in a controlled way without slamming or sticking open. If the door does not close properly, the device is faulty or misaligned.
What is the difference between frame depth and opening depth?
Frame depth is the thickness of the frame itself. Opening depth is the thickness of the wall or structure. The frame depth must match the product data sheet and fit within the opening depth without gaps.
When should I request a re-inspection?
Request a re-inspection when any deviation is found during the final inspection. The contractor must correct the issue in writing, and you must verify the correction before final acceptance.